SikaTop Armatec-110 EpoCem - Bonding Primer & Corrosion Protection
3-Component Coating with Corrosion Inhibitor
SikaTop Armatec-110 EpoCem is a cementitious epoxy resin compensated 3-component coating material containing a corrosion inhibitor. It is used as a bonding primer and for reinforcement corrosion protection. SikaTop Armatec-110 EpoCem meets the requirements of EN 1504-7.
Uses:
- Suitable for control of anodic areas (Principle 11, method 11.1 EN 1504-9)
- In concrete repair as corrosion protection for reinforcement.
- As a bonding primer on concrete and mortar.
- For Increasing cover in Low Cover Concrete rectification.
Features:
- Contains EpoCem technology - improved bonding agent
- Extended open times for repair mortars
- Compatible with most Sika MonoTop repair mortars
- Excellent adhesion to concrete and steel
- Contains corrosion inhibitor
- Certified for application under dynamic load conditions
- Good resistance to water and chloride penetration
- High shear strength
- Long pot life
- Easy to mix
- Can be brushed on or applied using spray gun
Product Information:
-
Composition: Portland cement, epoxy resin, selected aggregates and additives
-
Packaging: 8 kg kit: A (0.457 kg) + B (1.143 kg) + C (6.4 kg)
-
Shelf life: 12 months
-
Storage conditions: Store properly in undamaged original sealed packaging, in dry cool conditions between +5 °C and +25 °C.
-
Appearance and colour: Mixed components dark grey, Component A: white liquid, Component B: colourless liquid, Component C: dark grey powder
-
Density (A+B+C at 23 °C approx.): ~2.0 kg/l
Technical Information:
-
Tensile adhesion strength (after 28 days): ≥ 2.0 N/mm² (MPa) (EN 1542)
-
Shear adhesion strength (EN 15184): Pass
-
Coefficient of thermal expansion (EN 1770): ~18 x 10⁻⁶ 1/K
-
Permeability to carbon dioxide (AS/NZS 4548.5):
- Dry Film Thickness: 3.4 mm
- CO₂ Diffusion Coefficient: 1.6 x 10⁻⁵ cm²/sec
- Diffusion Resistance Coefficient (μ): 10390
- Equivalent Air Layer Thickness (R): 35 m
- Equivalent Thickness of Concrete (S c)*: 90 mm (* A μc value of 400 used for calculation)
-
Corrosion test (EN 15183): Pass
System Information:
SikaTop Armatec-110 EpoCem is part of the Sika repair system complying with EN 1504, including Bonding Primer / Reinforcement Corrosion Protection, Light Weight Repair Mortar (Sika MonoTop-352 series), Structural Repair Mortar (Sika MonoTop-412 series), and Pore Sealer and Levelling Mortar (Sika MonoTop-723 N).
Application Information
-
Consumption (as reinforcement corrosion protection): ~ 2 kg per m² per layer (~1 mm thick), minimum 2 layers (~2 mm total).
-
Consumption (as a bonding primer, substrate): > 1.5 to 2.0 kg per m²/mm dependent on substrate conditions.
-
Yield: Approx. 4lt per 8kg kit.
-
Ambient air temperature: +5 °C minimum; +30 °C maximum
-
Substrate temperature: +5 °C minimum; +30 °C maximum
-
Pot Life (at +20 °C): ~ 3 hours
-
Waiting time to overcoating (maximum before repair mortar application):
- +5 °C: 6 hours
- +10 °C: 5 hours
- +20 °C: 2 hours
- +30 °C: 1 hour
Application Instructions:
Substrate Quality / Pre-treatment: Concrete shall be free from dust, loose material, surface contamination. Remove delaminated, weak, damaged concrete. Pre-wet concrete thoroughly. Steel reinforcement: remove rust, scale, mortar, clean to SA 2 (ISO 8501-1) using abrasive blast cleaning or high-pressure water-blasting.
Mixing: Mix with a low speed (< 250 rpm) electric drill mixer. Shake components A and B. Pour A and B into a vessel and mix for 30 seconds. Slowly add component C while mixing. Mix all three for a minimum of 3 minutes, minimizing air entrapment. Let stand for 5–10 minutes until brushable consistency. DO NOT ADD WATER.
Application:
-
As reinforcement corrosion protection: Apply first layer (~1 mm) to cleaned reinforcement with a medium hard brush or spray gun. Apply the second layer when the first is hard to the fingernail (~2–3 hours at +20 °C). Apply subsequent repair mortars wet on dry.
-
As a bonding primer: Apply to prepared substrate with a medium hard brush or spray gun, ensuring it fills all pores (minimum 0.5 mm thickness). Apply subsequent repair mortars wet on wet. Protect freshly applied material from contamination and rain.
Curing Treatment: Protect fresh mortar from rain until set.
Cleaning of Equipment: Clean all tools with water immediately after use. Hardened material can only be mechanically removed.
Colour Accuracy Disclaimer: We have taken care to display the most accurate visuals of our products. However, we are not responsible for the colour accuracy of the device you are viewing our swatches on. These variations arise due to different computer monitors and devices (make, model and technology, as well as resolution, contrast and brightness control settings) in much the same way a scan will differ from an original image and a colour photocopy. Furthermore, coatings can exhibit variation in perceived colour depending on gloss level and application method. If you require a very specific colour match, please make your selection via actual swatches and colour boards available at our showroom.
Product Disclaimer: Ensure you read all product, technical and safety data sheets prior to application as liability falls on the applicator. All products must be applied in accordance with manufacturer’s recommended method.