{"product_id":"flowcrete-flowseal-uv-satin-polyurethane-sealer","title":"Flowcrete Flowseal UV Satin Two Pack Polyurethane Sealer 10Kg Kit Clear","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eFlowseal UV Satin is a two-component, UV stable, abrasion-resistant aliphatic polyurethane sealer designed to provide a durable Satin\/Semi gloss finish for Flowcrete flooring systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFlowseal UV Satin is designed as a final seal coat for decorative flooring systems and can also be applied directly onto honed and polished concrete.\u003c\/p\u003e\n\u003cp\u003eThe clear finish provides a protective satin seal while enhancing decorative flooring systems, while the coloured finish provides a UV stable coloured protective coating to further enhance the performance of Flowcrete flooring systems.\u003c\/p\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eWhere Can Flowseal UV Satin Be Used?\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFlowseal UV Satin is typically used as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA final seal coat for Flowcrete decorative flooring systems\u003c\/li\u003e\n\u003cli\u003eA UV stable protective sealer over compatible flooring systems\u003c\/li\u003e\n\u003cli\u003eA clear satin seal coat over honed and polished concrete\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFlowseal UV Satin Clear\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClear satin polyurethane sealer\u003c\/li\u003e\n\u003cli\u003eDesigned as a final seal coat for Flowcrete decorative systems\u003c\/li\u003e\n\u003cli\u003eSuitable for application directly onto honed and polished concrete\u003c\/li\u003e\n\u003cli\u003eEnhances the appearance of underlying flooring surfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eKey Benefits of Flowseal UV Satin\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUV stable polyurethane sealer\u003c\/li\u003e\n\u003cli\u003eSatin\/semi gloss finish appearance\u003c\/li\u003e\n\u003cli\u003eClear and coloured finish options\u003c\/li\u003e\n\u003cli\u003eHard wearing protective surface\u003c\/li\u003e\n\u003cli\u003eAbrasion resistant formulation\u003c\/li\u003e\n\u003cli\u003eChemical resistant formulation\u003c\/li\u003e\n\u003cli\u003eRoller applied for excellent finishing\u003c\/li\u003e\n\u003cli\u003eEnhances Flowcrete flooring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupplied as A+B pack\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBase A: 7.94kg (without pigment)\u003c\/li\u003e\n\u003cli\u003eHardener B: 2.06kg\u003c\/li\u003e\n\u003cli\u003eKit size: 10kg\u003c\/li\u003e\n\u003cli\u003eVolume: Approximately 9.1 litres\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDensity: Approximately 1.1kg\/L (combined)\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSolids content: Approximately 55% by weight\u003c\/li\u003e\n\u003cli\u003eFinish: Satin\u003c\/li\u003e\n\u003cli\u003eColour: Clear\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCoverage Rates\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eSurface\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCoat\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCoverage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"border: 1px solid #ccc; padding: 10px;\"\u003eOver Concrete\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eFirst coat\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0.2 kg\/m² (approx. 6m²\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eSecond coat\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0.15 kg\/m² (approx. 8m²\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"border: 1px solid #ccc; padding: 10px;\"\u003eOver Compatible Flake Flooring Systems\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eFirst coat\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0.2 kg\/m² (approx. 6m²\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eSecond coat\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0.2 kg\/m² (approx. 6m²\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eOptional third coat\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0.15 kg\/m² (approx. 8m²\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eSurface Preparation\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConcrete or screed substrate must have minimum strength of 25 N\/mm²\u003c\/li\u003e\n\u003cli\u003eSurface must be free from laitance, dust, and contamination\u003c\/li\u003e\n\u003cli\u003eSubstrate should be dry to 75% RH according to ASTM F2170 (AS1884:2012)\u003c\/li\u003e\n\u003cli\u003eSlab-on-ground concrete must have an effective damp proof membrane in place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMixing Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eUse complete pre-weighed packs for optimum performance.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eIf packs are proportioned, use accurate digital scales.\u003c\/li\u003e\n\u003cli\u003ePre-mix Base A to redistribute any settlement.\u003c\/li\u003e\n\u003cli\u003eAdd all Hardener B into Base A.\u003c\/li\u003e\n\u003cli\u003eMix using a slow-speed drill with helical spinner head for 90 seconds.\u003c\/li\u003e\n\u003cli\u003eAvoid entraining air during mixing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDo not add solvents such as Xylene, MEK, or Acetone to Flowseal UV Satin.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eApplication Conditions\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecommended material and substrate temperature: 15°C–35°C\u003c\/li\u003e\n\u003cli\u003eMinimum application temperature: 10°C\u003c\/li\u003e\n\u003cli\u003eSubstrate temperature must remain 3°C above dew point during application and curing\u003c\/li\u003e\n\u003cli\u003eTemperatures should not fall below 5°C within 24 hours after application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eWorking Time \/ Pot Life\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReady-mixed product should be used within 20 minutes at 20°C\u003c\/li\u003e\n\u003cli\u003eHigher temperatures or leaving material in the bucket will reduce working time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eCuring Times (at 20°C)\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum overcoating time: 8 hours\u003c\/li\u003e\n\u003cli\u003eMaximum overcoating time: 24 hours\u003c\/li\u003e\n\u003cli\u003eFoot traffic: 24 hours\u003c\/li\u003e\n\u003cli\u003eVehicular traffic: 72 hours\u003c\/li\u003e\n\u003cli\u003eFull chemical cure: 7 days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eFull chemical resistance is achieved after approximately 5–7 days.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eImportant Note:\u003c\/strong\u003e\u003cbr\u003eAlways refer to the latest Flowseal UV Satin Product Datasheet, Technical Data Sheet, and Safety Data Sheet for complete technical information, application requirements, limitations, and safety instructions before use.\u003c\/em\u003e\u003c\/p\u003e","brand":"Flowcrete","offers":[{"title":"Default Title","offer_id":41327233957952,"sku":"A1KMY600176","price":439.17,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/6210\/1824\/files\/flowcreteflowprimeepoxyprimer_646dee13-ab32-4074-95db-e500ce89db2c.jpg?v=1785993551","url":"https:\/\/protradewarehouse.com.au\/products\/flowcrete-flowseal-uv-satin-polyurethane-sealer","provider":"Protrade Warehouse | Trade \u0026 DIY Supplies Australia-Wide","version":"1.0","type":"link"}